{"product_id":"neurotrac-myoplus-pro-single-channel-biofeedback","title":"Neurotrac Myoplus Pro \/ Single Channel Biofeedback","description":"\u003ch2\u003eNeurotrac Myoplus Pro \/ Single Channel Biofeedback Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQuick answer:\u003c\/strong\u003e The new user friendly touch screen based interface makes it a self-explanatory unit with interactive learning on the go, including electrode placement, running EMG graph, EMG biofeedback Games and Templates as well as many other helpful tools.\u003c\/p\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eThe new user friendly touch screen based interface makes it a self-explanatory unit with interactive learning on the go, including electrode placement, running EMG graph, EMG biofeedback Games and Templates as well as many other helpful tools.\u003c\/li\u003e\r\n\u003cli\u003ePre-set programmes for Incontinence treatment (including a special programme for the treatment of incontinence by stimulating the nervous tibialis posterior with self-adhesive electrodes) and neuro-muscular Rehabilitation.\u003c\/li\u003e\r\n\u003cli\u003eSupplied with Rubber sleeve with stand and lanyard attachment option.\u003c\/li\u003e\r\n\u003cli\u003eDesigned for Physiotherapist in mind to be used as a portable tool. Suitable as a personal trainer for in-clinic or home use (under guidance).\u003c\/li\u003e\r\n\u003cli\u003eSingle channel EMG (Biofeedback) combined with 1 channel of NMES (stimulation).\u003c\/li\u003e\r\n\u003cli\u003eSingle channel ETS (EMG triggered stimulation) with single channel stimulation.\u003c\/li\u003e\r\n\u003cli\u003eSimple single-phase or multiphase operation: multiphase allows EMG\/ETS\/STIM to be combined in one programme.\u003c\/li\u003e\r\n\u003cli\u003eMultilingual full color display screen and voice prompts for Biofeedback.\u003c\/li\u003e\r\n\u003cli\u003eManual and Automatic threshold control.\u003c\/li\u003e\r\n\u003cli\u003eEMG Biofeedback between stimulation (muscle activity and tiredness indication when using muscle stimulation).\u003c\/li\u003e\r\n\u003cli\u003eStand alone device or used in conjunction with established multilingual software.\u003c\/li\u003e\r\n\u003cli\u003eUp to 10 meters of wireless (Bluetooth) connection for NeuroTrac Software.\u003c\/li\u003e\r\n\u003cli\u003eFor home users: Produces and prints (with the optional PC Software) the comprehensive patient progress reports on a day to day basis providing average readings on work\/rest, peak, onset and muscle release times, work and rest deviations and the average mA current.\u003c\/li\u003e\r\n\u003cli\u003eUsed as a learning tool for both patient and clinician with emphasis on improving treatment techniques in the use of EMG and Neuromuscular stimulation.\u003c\/li\u003e\r\n\u003cli\u003eFrom December 16th all electrodes have been sold separately under our ISO regulations.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cstrong\u003eEMG\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e1.0 Single channel EMG\u003c\/li\u003e\r\n\u003cli\u003e1.1 EMG Range: 0.2 to 2000 μV RMS (continuous)\u003c\/li\u003e\r\n\u003cli\u003e1.2 Sensitivity: 0.l μV RMS\u003c\/li\u003e\r\n\u003cli\u003e1.3 Accuracy: 4% of μV reading +\/-0.3 μV at 200 Hz\u003c\/li\u003e\r\n\u003cli\u003e1.4 Selectable Bandpass filter – 3db Bandwidth,\u003c\/li\u003e\r\n\u003cul\u003e\r\n\u003cli\u003ea. Wide: 18 Hz +\/- 4 Hz to 370 Hz +\/- 10% – Reading below 235 microvolts 10 Hz +\/-3 Hz to 370 Hz +\/- 10% – Reading above 235 microvolts\u003c\/li\u003e\r\n\u003cli\u003eb. Narrow: 100 Hz +\/- 5% to 370 Hz +\/- 10%\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cli\u003e1.5 Notch filter: 50 Hz (Canada 60Hz) – 33 dbs (0. 1% accuracy)\u003c\/li\u003e\r\n\u003cli\u003e1.6 Common Mode Rejection Ratio: 130 dbs Minimum @ 50 Hz\u003c\/li\u003e\r\n\u003cli\u003e1.7 Work \/ Rest periods: 2-99 seconds\u003c\/li\u003e\r\n\u003cli\u003e1.8 Number of Trials: 2-99\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cstrong\u003eNMES, TENS and ETS\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e2.1 Single channel Stimulator\u003c\/li\u003e\r\n\u003cli\u003e2.2 Amplitude: 0-90 mA into 500 Ohm load – actual mA will tend to be less than indicated due to Electrode impedance: at 1000 Ohms load (Electrodes in poor condition) the maximum will be limited to 75 mA, at 1500 Ohms load the maximum will be limited to 50 mA.\u003c\/li\u003e\r\n\u003cli\u003e2.3 Type: Constant current, maximum output voltage 70 Volts +5 \/ -10 Volts\u003c\/li\u003e\r\n\u003cli\u003e2.4 Waveform: Symmetrical, rectangular, bi-phasic with net zero DC current\u003c\/li\u003e\r\n\u003cli\u003e2.5 Pulse width selection: 50-330 μS (10% accuracy)\u003c\/li\u003e\r\n\u003cli\u003e2.6 Pulse rate selection: 2-100 Hz (5% accuracy)\u003c\/li\u003e\r\n\u003cli\u003e2.7 Work \/ Rest periods: 2-99 seconds\u003c\/li\u003e\r\n\u003cli\u003e2.8 Time 1 – 99 minutes\u003c\/li\u003e\r\n\u003cli\u003e2.9 Ramp up time: 0.1 – 9.9 seconds\u003c\/li\u003e\r\n\u003cli\u003e2.10 Preset and user programmable treatment Programs\u003c\/li\u003e\r\n\u003cli\u003e2.11 Automatic output shut off with detection of open electrode above 10 mA (+\/- 2mA).\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003cul\u003e\r\n\u003cli\u003eBattery set: 4 x 1.5V, AAA battery.\u003c\/li\u003e\r\n\u003cli\u003eLow battery indication at 5.4 volts +\/- 0.2 volts, automatic shut off when voltage drops below the low indication. Replace the batteries immediately!\u003c\/li\u003e\r\n\u003cli\u003eThe device goes off automatically when not in use (energy saving): for example when in settings and no key pressed over 1 minute, when in stimulation mode (home screen) and all channels are 0mA.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003eWho Is This Product For?\u003c\/h2\u003e\n\u003cp\u003eThis product may suit customers and healthcare professionals comparing products for the stated clinical, therapy or personal-care purpose. Always review the supplied specifications and available options before ordering.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is Neurotrac Myoplus Pro \/ Single Channel Biofeedback?\u003c\/h3\u003e\n\u003cp\u003eThe new user friendly touch screen based interface makes it a self-explanatory unit with interactive learning on the go, including electrode placement, running EMG graph, EMG biofeedback Games and Templates as well as many other helpful tools.\u003c\/p\u003e\n\u003ch3\u003eHow do I choose the correct option?\u003c\/h3\u003e\n\u003cp\u003eConfirm the stated dimensions, compatibility, intended use and any clinical or facility requirements shown in the product information.\u003c\/p\u003e\n\u003ch3\u003eWhere can I order Neurotrac Myoplus Pro \/ Single Channel Biofeedback in Australia?\u003c\/h3\u003e\n\u003cp\u003eNeurotrac Myoplus Pro \/ Single Channel Biofeedback is available online from Rehabeshop. Delivery availability and charges for Australian addresses are shown during checkout.\u003c\/p\u003e\n\u003ch2\u003eImportant Information\u003c\/h2\u003e\n\u003cp\u003eUse this product according to the manufacturer's instructions and applicable clinical, manual-handling or infection-control procedures. Confirm dimensions, compatibility, training and facility requirements before ordering.\u003c\/p\u003e\n\u003cp\u003eExplore related products in our \u003ca href=\"\/collections\/clinical-therapy-tools-1\"\u003eClinical \u0026amp; Therapy Tools\u003c\/a\u003e collection.\u003c\/p\u003e","brand":"NeuroTrac","offers":[{"title":"Default Title","offer_id":48175179071639,"sku":"2305","price":999.17,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/7115\/7655\/files\/myopluspro-main-570x708.jpg?v=1787899240","url":"https:\/\/rehabeshop.com.au\/products\/neurotrac-myoplus-pro-single-channel-biofeedback","provider":"Rehabeshop","version":"1.0","type":"link"}